50G 80ch TAWG

Click for original picture
Channels: 80 Ch
Channel Spacing: 50 GHz
Reference Pass-band: ± 0.05 nm
Fob Price: Discuss personally 
Port: Guangzhou/Shenzhen
Supply Ability: 20000
Payment Terms: delivery withindays since payment
Location: China Guangxi
  Janice Chen    Contact Now 询价
Not exactly what you want? Post a quick Buying Request !
 
 
Product Detail

Brand:GLSUN

Description:1. The specifications serve for C-band 100GHz Flat-top MUX/DEMUX in DWDM system.2. The AWG module includes an integrated internal thermal control circuit.

Origin:China Guangxi

Model:50G 80ch TAWG

MOQ:100Unit/Units

FOB:perUnit/Units1--5000USD

Port:Guangzhou/Shenzhen

Payment Terms:T/T

Supply Ablility:20000Unit/Units

Supply Time:Month

Delivery Time:2016-10-31

Packaging Details:by carton box

Product detail: 

INTRODUCTION:

Application Note

1. The specifications serve for C-band 100GHz Flat-top MUX/DEMUX in DWDM system.

2. The AWG module includes an integrated internal thermal control circuit.

Optical Specifications

 

Optical Specifications

Optical signal transmission characteristics

 

Parameters

 

Notes

Specifications

 

Units

Min

Max

Channels

 

80

Ch

Channel Spacing

 

50

GHz

Reference Pass-band

Relative to ITU Grid

± 0.05

nm

ITU Frequency

C-band

192.1

196.05

THz

ITU Wavelength

C-band

1529.163

1560.606

nm

 

Center Wavelength

Accuracy

Maximum of the absolute deviation of the 3 dB center wavelength from ITU grid over all channels

 

 

± 0.024

nm

 

0.5 dB Bandwidth

0.5 dB from min Insertion Loss, full width, worst case polarization

 

0.1

 

 

nm

 

1dB Bandwidth

1dB from min Insertion Loss, full width, worst

case polarization

 

0.2

 

 

nm

 

3dB Bandwidth

3 dB from min Insertion Loss, full width, worst case polarization

 

0.3

 

 

nm

 

20 dB bandwidth

20 dB from min Insertion Loss, full width, worst case polarization

 

 

0.6

 

nm

 

Insertion Loss

Maximum of the insertion loss across the ITU

pass-band over all channels

 

 

7.0

 

dB

 

Ripple

Maximum of the loss variance across the ITU

pass-band over all channels

 

 

0.5

 

dB

Insertion Loss

Uniformity

Maximum insertion loss variance across all channels

 

 

1.5

 

dB

Adjacent Channel

Isolation

Ratio of peak transmission to the maximum transmission over both adjacent pass-bands

 

25

 

 

dB

 

Non-Adjacent

Channel Isolation

Ratio of peak transmission in channel pass- bands to maximum transmission over all non- adjacent pass-bands

 

30

 

 

dB

 

Total Crosstalk

Ratio of power in channel to power in all other pass-bands

 

20

 

 

dB

 

 

Polarization

Dependent Loss

Maximum ratio of transmissions over all polarization states, over the ITU pass-band

 

 

0.5

 

dB

 

 

Return Loss

 

40

 

dB

 

Polarization Mode

Delay (PMD)

 

In Reference Passband over all channels

 

 

0.5

 

ps

 

Chromatic Dispersion

In Reference Passband over all channels

-20

20

ps/nm

 

All parameters are the worst-case across clear ITU window, over all temperature range (-5°C to 65°C) and all states of polarization. Connector loss is included.

 

Environmental Conditions and Maximum Ratings

 

Parameters

 

Notes

Specifications

 

Units

Min

Typ

Max

Operating Temperature

 

-5

 

+65

°C

Storage Temperature

 

-40

 

+85

°C

Relative Humidity

 

5

 

 