APEX heat capacity of calorimeter petroleum engineering new product

Click for original picture
Fob Price: 10000.00 USD/ 
MOQ: 1  
Payment Terms: delivery withindays since payment
Location: China
  Ms. yang li    Contact Now 询价
Not exactly what you want? Post a quick Buying Request !
 
 
Product Detail

Brand:aa

Product detail:

1, APEX heat capacity of calorimeter petroleum engineering called calorimeters, said domestic kcal instrument,
the main measure of coal, straw, bio-fuels and other solid amount of heat,
but also measurable heat oil and other liquids, mainly for thermal power, cement, coal, new energy and other fields.

2, APEX heat capacity of calorimeter petroleum engineering widely used.Which determines the price.

3, APEX heat capacity of calorimeter petroleum engineering widely used for biological fuels, solid fuel,
liquid fuel heating value evaluation.

4, APEX heat capacity of calorimeter petroleum engineering according to ISO1928: 1995 manufacturing. As inexpensive,
loved by the users. High market share in China.

5,APEX heat capacity of calorimeter petroleum engineering 90s of last century began production.
Meet SME customers for coal, straw, bio-fuels,
oil and other objects in the identification of the combustion heat demand.

6,APEX heat capacity of calorimeter petroleum engineering commonly used assessment fuel combustion heat
can also be used to calculate the ratio of coal bricks.

APEX heat capacity of calorimeter petroleum engineering advantage

1, APEX heat capacity of calorimeter petroleum engineering has been focus on environmental sustainability .
The R & D products , the use of low-power components .
Achieve energy saving requirements. Energy conservation, we start from . Instrument itself is used for environmental monitoring ,
self- and even more so . Start an instant power does not exceed 1000W.
During normal operation, no more than 500W.

2, fast APEX APEX heat capacity of calorimeter petroleum engineering is improved after years of research and development ,
according to the latest international standards development .
Beckman test speed faster than the old more than 20 minutes .
Accuracy unchanged. And , you can automatically called water , automatic timed ignition,
automatic measurement of temperature, saving a lot of preparation time .

3 , accurate APEX heat capacity of calorimeter petroleum engineering according to ISO1928: 1995 requires the development
of accuracy in full compliance with ISO1928: 1995 requirements.
And to some extent than ISO1928: 1995 standards.

4 , maturity APEX heat capacity of calorimeter petroleum engineering products mature and stable ,
reliable quality. Durability is very high. The market has been the test of time and identification.
The majority of users are trustworthy models.

5 , cost and operation and maintenance costs APEX heat capacity of calorimeter petroleum engineering because low energy consumption. Operating costs are not high .
Degree of automation is superior. Greatly reduce labor and maintenance costs . During use .
Human labor cost reduction is the process of liberation . Them . We focused on our customers ,
the implementation of low-cost supply of spare parts and consumables . Reduce the cost of consumables used .

6 , the operation APEX heat capacity of calorimeter petroleum engineering by our many years of continuous improvement.
Has a higher degree of customer premise practical as possible
within the scope of our technical strength . Increased automation better .
Operation more simple device . Equipment for laboratory technicians is increasing demand is low.
In the future. We hope. Anyone may not be trained to use our equipment .

We have now done . Automatic water, automatic drainage ,
automatic printing , automatic calculation , automatic constant temperature inside and outside the barrel ,
automatic ignition, automatic temperature compensation, and other functions.

7 , the service APEX services are possible to meet more customer needs.
Products , customization, training , and other services that we will try to do our best.

And . Now use the Internet to build provides remote maintenance, remote training the ability to teach .

For the supply of goods services. increased from merely providing
maritime shipping services. Changes can now be based on customer demand ,
air or express delivery services. So that your home can directly get the desired device

8 , the performance APEX heat capacity of calorimeter petroleum engineering stable performance, can be a long run .
We conducted two ways of stabilization method .
1 is a temperature correction using the software . The temperature of the outer cylinder 2 additional cooling means

1, APEX heat capacity of calorimeter petroleum engineering structure

Let the upper front power
switch : Power lead socket in the back of the upper instrument . APEX heat capacity of calorimeter petroleum engineering interior
include: SCM system , the amount of heating systems , water systems, electrical
control systems, power supplies and other accessories.

APEX heat capacity of calorimeter petroleum engineering SCM system comprising: a monolithic SBC ,
LCD, panel printer , keyboard , real time clock , etc. ;
calorimetry systems include : the amount of heat tube, oxygen bomb , temperature probe ( two-way ) , the temperature signal conditioning and conversion system ,
the ignition circuit and the inner cylinder mixer .

2, APEX heat capacity of calorimeter petroleum engineering function

(1), APEX heat capacity of calorimeter petroleum engineering using advanced single-chip microcomputer system ,
complete with instrumentation and unique water system
and the amount of thermal systems to auto-complete :
inner tube replacement and quantitative water cooling : automatic mixing , automatic ignition ,
data acquisition and processing, data storage , instrument status display , audible alert or alarm ,
printouts various reports . With a fully functional , accurate measurement,
calculation fine , intuitive display, Chinese interface, easy operation , high durability and
easy maintenance are intelligent automatic heat measuring device .

Simply install bomb lab technician manual operation , the instrument automatically completed by other processes .

(2), APEX heat capacity of calorimeter petroleum engineering AD imported high-grade large-scale integrated devices ,
to achieve dual high-speed , high-precision temperature measurement makes the operation easier
and more accurate measurements .

(3), APEX heat capacity of calorimeter petroleum engineering using large size graphic LCD display to display the various states of the instrument ,
data and graphics. Chinese menu interface , intuitive , friendly
and easy to use. Analog display temperature curve during the test , vivid and intuitive.

(4), APEX heat capacity of calorimeter petroleum engineering panel printer output using various reports .
Print format allows users to customize , or Jane or full , ready to set .

(5), APEX heat capacity of calorimeter petroleum engineering uses advanced real-time clock circuit can be displayed on the screen with the current date
and time are automatically recorded during the test time of completion of the test , and printed on the report ,
the test report more timely : to permanently record second date of calibration of the equipment to prepare for the next instrument
calibration confirmation date . Normal time clock circuit outage .

3,APEX heat capacity of calorimeter petroleum engineering specifications

( 1 ) , the heat capacity ( water equivalent ) : about 10500 J / K ( co 2500cal / K)

( 2 ) , oxygen bomb : Working pressure ( filling oxygen ) :2.8-3 .0 Mpa Max 3.2Mpa

Pressure test ( hydrostatic ): 20Mpa

Volumetric : 300mL

Weight : 2.5KS

Dimensions : Φ86mm × l81mm

( 3 ) , the inner barrel of water : about 2100mL

( 4 ) , the outer sleeve and water storage cartridges Capacity: Approximately 20L

( 5 ) , temperature measurement system :

Let the inner tube ( the probe in the roof ) and the outer sleeve ( probe with flange mounted on the outer wall of the sleeve ) ends ,
the corresponding screen is displayed as : IT or OT:

Display range : 0-65.535 ℃

Display resolution : 0.001 ℃

( 6 ) , heat capacity Repeatability: better than 0.1%

4, style="color:#0000cd;">APEX heat capacity of calorimeter petroleum engineering Application Operation

APEX heat capacity of calorimeter petroleum engineering calorimeter high degree of automation . Just a few steps to get the desired test results . Is very simple.

( 1 ) : Samples were weighed on a balance

( 2 ) : Weigh the sample into a bomb inside , and use our gift of automatic oxygenation apparatus filled with oxygen.

( 3 ) : the bomb into the calorimeter . And the sample weight and other data input calorimeter .

( 4 ) : Click : Start

( 5 ) : Waiting

( 6 ) : Wait......

( 7 ): OK. Results are automatically begin printing

1, APEX heat capacity of calorimeter petroleum engineering calorimeter characteristics

 

 
more..Other products from this supplier

[ ProductsSearch ]  [ [ Print ]  [ Close ]


Copyright © 2004 ChinaAseanTrade.com All rights reserved
中国-东盟自由贸易网版权所有@2004 沪lCP证05013507号

沪公网安备 31010102002066号