Milk flowmeter/vortex flowmeter
| Parameter of vortex flow meter | |||||
| Measured Mediums | liquids, gases and steams (NOTE: the mediums should be unidirectional or can be seen as unidirectional.) | ||||
| When the dryness of saturated steams ≥85%, they can be seen as unidirectional. | |||||
| Temperature of Mediums | - 40°C ~ + 350°C | ||||
| Pressure of Mediums | 1.6MPa, 2.5MPa, 4.0 MPa | ||||
| For over 4.0 MPa, please contact us freely, for it needs special customization. | |||||
| Accuracy | 1.0; 1.5 | ||||
| Span Rate | 1:8 ~ 1:30(compared with the standard atmospheric pressure) | ||||
| 1:8 ~ 1:40 ( compared with the nominal temperature water) | |||||
| Flow Range | Liquids: 0.4 ~ 7.0 m/s | ||||
| Gases: 4.0 ~ 60.0 m/s | |||||
| Steams: 5.0 ~ 70.0 m/s | |||||
| Nominal Diameter | DN 25, 40, 50, 65, 80, 100, 125, 150, 200, 250,300 mm | ||||
| Materials | 1Cr18Ni9Ti | ||||
| Reynolds No. | Normally, 2*104 ~ 7*106 | ||||
| Resistance Coefficient | Cd ≤ 2.6 | ||||
| Licensed Vibration Acceleration | LUGB type ≤ 0.2g | ||||
| Class of Protection | IP65 | ||||
| Class of Explosion-Proof | Intrinsically Safe Explosion-Proof: Exia II CT2 ~ CT6 | ||||
| Explosion Suppression: Exid II CT4 | |||||
| Conditions of Surroundings | Temperature of Surroundings: | Non-Explosion Proof Surroundings: -40°C~ +55°C | |||
| Explosion-Proof Surroundings: -20°C~ +55°C | |||||
| Relative Humidity: | ≤ 85% | ||||
| Atmospheric Pressure: | 86 ~ 106 kPa | ||||
| Power Supply | Non-Explosion Proof Type | Pulse type: | +12 VDC ( the output current is 4 ~ 20mA) | ||
| Current type: | +24 VDC ( the output current is 4~ 20mA) | ||||
| Explosion-Proof Type | Current type: | +24 VDC ( the output current is 4~20mA) | |||
| Output Signal | Frequency pulse signal 2~3000Hz, low level voltage ≤1V, high level voltage ≥ 6V | ||||
| Two-wire system 4 ~ 20mA signal (isolation output), load ≤ 500Ω. | |||||
| Measure range of vortex flow meter | ||
| Diameter (mm) | Water | Gases in the Normal Temperature and Pressure |
| Range of Standard Measurement (m3/h) | Range of Standard Measurement (m3/h) | |
| 25 | 2 ~ 16 | 8~60 |
| 32 | 1.5~15 | 14~100 |
| 40 | 3~30 | 18~180 |
| 50 | 4~40 | 30~300 |
| 65 | 6~60 | 50~500 |
| 80 | 13~130 | 70~700 |
| 100 | 20~200 | 100~1000 |
| 125 | 36~360 | 150~1500 |
| 150 | 50~500 | 200~2000 |
| 200 | 100~1000 | 400~4000 |
| 250 | 150~1500 | 600~6000 |
| 300 | 200~2000 | 1000~10000 |
We are Kaifeng Qingtianweiye Flow Instrument Co., Ltd,a subsidiary of listed company Henan SunTront Tec Co.,Ltd.Our head office is a listed company since 2011 and its main products is intelligent electricity meters,while Our company mainly engaged in electromagnetic flow meter.